EMC Question of the Week: March 9, 2026

circuit board with a shielded cable attached and an unknown connection between the shield and the board

A shielded cable connects to a circuit board mounted in a plastic enclosure. To minimize EM emissions and maximize EM immunity, the cable shield should generally connect to the circuit board ground planes   

  1. directly
  2. through an RC filter
  3. through a CM choke
  4. through ferrites

Answer

The best answer is “a.” Cable shields serve two purposes. They block fields created by common-mode currents on the inner wires and return those currents to the board. They also block external fields which puts a common-mode current on the external surface of the shield. The shield can't serve either of these purposes effectively if it doesn't make a good high-frequency connection to the board's EMC ground.

If the common-mode currents induced on the interior of the shield are forced to flow through any impedance on their way back to their source, a common-mode voltage will be developed that drives the cable shield relative to the board. If externally induced currents are blocked from reaching the board ground, a voltage will develop between the cable shield exterior and the board. This voltage will drive the wires inside the shield and induce common-mode currents on those wires. 

Of course, shielded cables work best when they connect devices that have a metal chassis or a shielded enclosure. In this situation, the cable shield should always make a good connection to the chassis or enclosure. If the shield is returning significant common-mode currents to the board, it also needs to make a good connection to the board. 

Have a comment or question regarding this solution? We'd like to hear from you. Email us at This email address is being protected from spambots. You need JavaScript enabled to view it..